Basic parameters:
  • Chamber pressure pchamber : 5.33->20.82 mPa (request: 20 mPa)
  • Chamber temperature: 13 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7780 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.99 over 9.27 to 17.26 [ms]
  • Mean toroidal magnetic field Bt: 0.112 T
  • Mean plasma current: 2.7 kA
  • Mean Uloop: 7.8 V
  • Break down voltage: 11.0 V
  • Plasma total charge: 24.8 C
  • Ohmic heating power: 21.1 kW
  • Q edge: 3.7
  • Central electron temperature: 44.3 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK