Golem shot: 5205

2011-04-07 - 155009

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 4.03->19.81 mPa (request: 20 mPa)
  • Chamber temperature: 93 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1225 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.96 over 9.78 to 17.74 [ms]
  • Mean toroidal magnetic field Bt: 0.254 T
  • Mean plasma current: 1.8 kA
  • Mean Uloop: 7.2 V
  • Break down voltage: 8.8 V
  • Plasma total charge: 17.2 C
  • Ohmic heating power: 13.0 kW
  • Q edge: 12.7
  • Central electron temperature: 35.6 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK