Golem shot: 5207

2011-04-07 - 184010

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 3.70->26.42 mPa (request: 20 mPa)
  • Chamber temperature: 8 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2012 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.32 over 7.92 to 16.24 [ms]
  • Mean toroidal magnetic field Bt: 0.118 T
  • Mean plasma current: 2.3 kA
  • Mean Uloop: 5.7 V
  • Break down voltage: 8.9 V
  • Plasma total charge: 18.5 C
  • Ohmic heating power: 13.1 kW
  • Q edge: 4.6
  • Central electron temperature: 49.0 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and