Golem shot: 5209

2011-04-07 - 190506

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 4.06->20.98 mPa (request: 20 mPa)
  • Chamber temperature: 77 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3539 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.5 over 15.79 to 22.29 [ms]
  • Mean toroidal magnetic field Bt: 0.240 T
  • Mean plasma current: 5.1 kA
  • Mean Uloop: 5.4 V
  • Break down voltage: 10.5 V
  • Plasma total charge: 80.4 C
  • Ohmic heating power: 27.5 kW
  • Q edge: 4.2
  • Central electron temperature: 86.4 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and