Golem shot: 5213

2011-04-07 - 195434

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 4.03->20.51 mPa (request: 20 mPa)
  • Chamber temperature: 72 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6524 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.5 over 17.44 to 23.94 [ms]
  • Mean toroidal magnetic field Bt: 0.284 T
  • Mean plasma current: 4.3 kA
  • Mean Uloop: 4.6 V
  • Break down voltage: 9.2 V
  • Plasma total charge: 75.7 C
  • Ohmic heating power: 19.8 kW
  • Q edge: 6.0
  • Central electron temperature: 85.9 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and