Golem shot: 5226

2011-04-11 - 150852

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 3.94->22.14 mPa (request: 20 mPa)
  • Chamber temperature: grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4070 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.94 over 7.68 to 14.62 [ms]
  • Mean toroidal magnetic field Bt: 0.170 T
  • Mean plasma current: 1.9 kA
  • Mean Uloop: 9.4 V
  • Break down voltage: 11.0 V
  • Plasma total charge: 14.9 C
  • Ohmic heating power: 17.9 kW
  • Q edge: 8.1
  • Central electron temperature: 30.9 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Spectrograms_TO

Thanks to the specific help and