Golem shot: 5228

2011-04-11 - 151359

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 4.12->20.04 mPa (request: 20 mPa)
  • Chamber temperature: grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4377 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.8 over 10.71 to 17.51 [ms]
  • Mean toroidal magnetic field Bt: 0.191 T
  • Mean plasma current: 2.7 kA
  • Mean Uloop: 8.5 V
  • Break down voltage: 10.8 V
  • Plasma total charge: 28.7 C
  • Ohmic heating power: 23.0 kW
  • Q edge: 6.4
  • Central electron temperature: 41.8 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Spectrograms_TO

Thanks to the specific help and