Golem shot: 5230

2011-04-11 - 154346

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 3.74->23.27 mPa (request: 20 mPa)
  • Chamber temperature: grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 277 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.44 over 10.48 to 17.92 [ms]
  • Mean toroidal magnetic field Bt: 0.206 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 8.3 V
  • Break down voltage: 15.3 V
  • Plasma total charge: 14.9 C
  • Ohmic heating power: 11.6 kW
  • Q edge: 13.3
  • Central electron temperature: 27.4 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Spectrograms_TO

Thanks to the specific help and