Golem shot: 5231

2011-04-11 - 155419

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 3.74->20.19 mPa (request: 20 mPa)
  • Chamber temperature: grad C
  • CBt capacitors (23 mF) charged to: 1300 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 3,5 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 100 V, triggered 4,5 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 928 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.67 over 10.62 to 19.29 [ms]
  • Mean toroidal magnetic field Bt: 0.288 T
  • Mean plasma current: 2.7 kA
  • Mean Uloop: 10.6 V
  • Break down voltage: 12.8 V
  • Plasma total charge: 28.8 C
  • Ohmic heating power: 28.6 kW
  • Q edge: 9.6
  • Central electron temperature: 36.1 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Spectrograms_TO

Thanks to the specific help and