Golem shot: 5232

2011-04-11 - 160209

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 3.74->19.96 mPa (request: 18 mPa)
  • Chamber temperature: grad C
  • CBt capacitors (23 mF) charged to: 1300 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 3,5 ms after Bt
  • CST capacitors (2.7 mF) charged to: 150 V, triggered 5,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1396 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.24 over 11.17 to 20.41 [ms]
  • Mean toroidal magnetic field Bt: 0.298 T
  • Mean plasma current: 2.6 kA
  • Mean Uloop: 10.4 V
  • Break down voltage: 14.5 V
  • Plasma total charge: 29.3 C
  • Ohmic heating power: 27.0 kW
  • Q edge: 10.3
  • Central electron temperature: 35.6 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Spectrograms_TO

Thanks to the specific help and