Shot (pre) comment: vacuum shot, measuring voltage on whole quadrupole | ||
7109 (22:16) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.25->3.25 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: again plasma, measuring voltage on whole quadrupole | ||
7108 (22:09) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.26->12.50 mPa ,Tch=100 °C. |
H2Fill:
![]() PrimReactor: PreIonization: ![]() | ![]() | |
Shot (pre) comment: plasma attempt | ||
7107 (22:05) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.24->10.08 mPa ,Tch=100 °C. |
H2Fill:
![]() PrimReactor: PreIonization: ![]() | ![]() | |
Shot (pre) comment: weird Uloop, again | ||
7106 (22:02) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.24->3.25 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: U_B up to 600 V | ||
7105 (22:00) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.25->3.25 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, testing quadrupole at 400 V CD | ||
7104 (21:57) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.26->3.27 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, testing quadrupole at 300 V CD | ||
7103 (21:56) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),300(2,0 ms),00(0,0 ms)) [V] | pH2=3.27->3.26 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, staying at U_CD 200 V - quadrupole reconnected | ||
7102 (21:55) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),200(2,0 ms),00(0,0 ms)) [V] | pH2=3.27->3.29 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, staying at U_CD 200 V - testing if there is possible short-circuit at higher voltage, using 1:100 resistor ratio for 4 turn inner coil | ||
7101 (21:50) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),200(2,0 ms),00(0,0 ms)) [V] | pH2=3.26->3.26 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, increasing U_CD to 200 V - testing if there is possible short-circuit at higher voltage | ||
7100 (21:43) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),200(2,0 ms),00(0,0 ms)) [V] | pH2=3.29->3.26 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, increasing U_CD to 100 V - testing if there is possible short-circuit at higher voltage | ||
7099 (21:39) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),100(2,0 ms),00(0,0 ms)) [V] | pH2=3.39->3.39 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, still good Uloop, now also measuring voltage on top inner coils, 2 turns | ||
7098 (21:01) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),80(2,0 ms),00(0,0 ms)) [V] | pH2=3.41->3.40 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, still good Uloop, now measuring voltage on top inner coils, 4 turns | ||
7097 (20:55) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),80(2,0 ms),00(0,0 ms)) [V] | pH2=3.39->3.39 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, good Uloop, removed top inner coil voltage measurement, U_CD down to 80V | ||
7096 (20:52) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),80(2,0 ms),00(0,0 ms)) [V] | pH2=3.38->3.38 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, still bad Uloop, put back old photodiodes | ||
7095 (20:49) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),100(2,0 ms),00(0,0 ms)) [V] | pH2=3.36->3.38 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, still bad Uloop, Fluke still measuring - U_CD down to 100 V, Fluke range back to 60 A | ||
7094 (20:42) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),100(2,0 ms),00(0,0 ms)) [V] | pH2=3.36->3.38 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, Fluke still measuring - Fluke range changed to 600 A max, 5 mV/A | ||
7093 (20:34) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.41->3.43 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, Fluke still measuring - Fluke device repositioned further away from chamber | ||
7092 (20:30) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.45->3.43 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, Fluke still measuring - so different Fluke, again no conducter through Fluke | ||
7091 (20:25) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.47->3.47 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, good Uloop, but Fluke still measured current 10 A - no conducter through Fluke fg 20 | ||
7090 (20:19) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.47->3.45 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, good Uloop, but Fluke measured current 10 A - all top coils disconnected, U_B down to 100 V | ||
7089 (20:13) | (UB,UBD,UCD,UST)=(100,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.47->3.48 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, bad Uloop - top inner coil, 4 turns, put out of series | ||
7088 (20:04) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.45->3.45 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, bad Uloop - maybe induced current in coils - disconnected coils from power source | ||
7087 (19:56) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.44->3.47 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, DAS test, fluke up to 60 A - 50 mV/A | ||
7086 (19:46) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.41->3.43 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, measuring influence of the current through cables for toroidal coils on current measuer by Rogovski coil - now with cables for tor. mag. field in Rog. coil | ||
7085 (18:42) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.52->3.52 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() | |
Shot (pre) comment: vacuum shot, measuring influence of the current through cables for toroidal coils on current measuer by Rogovski coil | ||
7084 (18:36) | (UB,UBD,UCD,UST)=(600,00(3,0 ms),400(2,0 ms),00(0,0 ms)) [V] | pH2=3.51->3.51 mPa ,Tch=100 °C. |
H2Fill:
PrimReactor: PreIonization: | ![]() |