Comment: Investigating q_edge with different Bt

Golem shot: 8711

2012-05-10 - 212343



Basic parameters:
  • Chamber pressure pchamber : 3.09->10.00 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 300 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3080 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.11 over 1.455 to 9.565 [ms]
  • Mean toroidal magnetic field Bt: 0.021 T
  • Mean plasma current: 0.8 kA
  • Mean Uloop: V
  • Break down voltage: 13.2 V
  • Plasma total charge: 1.2 C
  • Ohmic heating power: 8.5 kW
  • Q edge: 2.4
  • Central electron temperature: 16.0 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Laszlo

Acknowledgement: ,
Thanks to the specific help and