Comment: Just runaway No:510 once more again

Golem shot: 9423

2012-06-29 - 154227



Basic parameters:
  • Chamber pressure pchamber : 0.64->10.00 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 300 V, triggered 4,5 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 4,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 9299 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.894 over 7.117 to 17.011 [ms]
  • Mean toroidal magnetic field Bt: 0.144 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: V
  • Break down voltage: 13.9 V
  • Plasma total charge: 11.0 C
  • Ohmic heating power: 18.6 kW
  • Q edge: 8.7
  • Central electron temperature: 22.0 eV

DAS:

NIturbo

NIbasic

NIstandard.ONN
Diagnostics: (configuration)

Flukes

HXR_OG

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and