Measurements are to be set up and shots initiated using the linux terminal of GOLEM tokamak, which can be seen on figure \ref{fig:command_control}. The exact address of it is provided by local operator just at the beginning of the session. The example of the controll command \lstinputlisting{Operation/Discharge/CommandControl/example.page} \begin{itemize} \item \GWhref{Tokamak/ToroidalMagneticField}{Toroidal magnetic field} ($B_t$) through the voltage of the toroidal field capacitor bank \GWparam{Infrastructure/ToroidalMagneticFieldCircuit/Capacitor/ChargingVoltage} .. parameter: --UBt \item Toroidal electric field ($E_t$) through the capacitor bank for the current drive \GWparam{Infrastructure/CurrentDriveFieldCircuit/Capacitor/ChargingVoltage} .. parameter: --Ucd \item The time delay between the triggers of the toroidal magnetic field and the current drive \GWparam{Infrastructure/TriggerSystem/Trigger3_CurrentDrive} .. parameter: --Tcd \item Hydrogen gas pressure ($p_{H2}$), range: $0-100 \;\rm mPa$ .. parameter: --pressure \item Preionization ON/OFF .. parameter: --preionization \end{itemize}