--- format: markdown title: Monitoring of radiation II ... #**Aim** * monitoring of radiation caused by interaction of fast electrons (runaway electrons) with first wall of Golem tokamak (probably limiter) #**Basic Information** * total amount of dosimeters 34 - 30 located in the vicinity of tokamak, 4 used as reference (background radiation) * date of installation: 3.1. 2019 (before shot 29056) * date of removing: 17.4. 2019 (before shot 30352) #**Setup** * each dosimeter located on right side of toroidal field coil: n. 1 - 28 upper and 29 - 30 down | Number of dosimeter | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | |------------------------|---|---|---|---|---|---|---|---|---|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----| | Number of toroidal field coil | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 17 | 18 | #**Photos** ![Position of first dosimeter](/Production/Safety/Radiation/OSLmonitoring/II/dozimetr_01.jpg) ![Positions of dosimeters II](/Production/Safety/Radiation/OSLmonitoring/II/dozimentr_02-04.jpg) ![Positions of dosimeters III - position of n. 17 (up on TFC 17) and 29 (down on TFC 17) is visible](/Production/Safety/Radiation/OSLmonitoring/II/dozimeter_17-29.jpg) ![Positions of dosimeters IV - detail on position of dosimeters 29 and 30 (TFC 17,18 down)](/Production/Safety/Radiation/OSLmonitoring/II/dozimeter_29-30.jpg) #**Analysis** perform analysis #**Results** add results