Comment: Groupe2-PlasmaF1

Golem shot: 7334

2012-02-17 - 122526



Basic parameters:
  • Chamber pressure pchamber : 3.58->12.79 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 15431 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.071 over 7.78 to 16.851 [ms]
  • Mean toroidal magnetic field Bt: 0.230 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 10.6 V
  • Plasma total charge: 10.6 C
  • Ohmic heating power: 13.9 kW
  • Q edge: 14.8
  • Central electron temperature: 24.4 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

IPCameraChamber

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Spectrograms_TO

Thanks to the specific help and