\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem #36877

Tokamak GOLEM - Shot Database - #36877

The date of discharge execution21-06-01 12:59:49 [Shot logbook]
The session mission21_ST_MegiD_IsotopicStudies --> Isotopic studies
The session ID36859
The discharge commentPROBLEM with probe position, from 70 again
Discharge command./Dirigent.sh --discharge --UBt 1200 --TBt 1000 --Ucd 700 --Tcd 2000 --preionization 1 --gas He --pressure 15 --comment "PROBLEM with probe position, from 70 again" --diagnostics_langballpenprobe "r_LP_tip=70, f_fg=5000, u_fg=8, r_i=27" --ScanDefinition "36868 36869 36871 36873"

     Technological parameters

    Plasma:

    Plasma parameters:

Basic Diagnostics    

On stage diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 



         



 



         



 



Other diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 



Analysis

NameAnalysis results


Scan issues

for 36868 36869 36871 36873 + 36877







#36868     ./Dirigent.sh --discharge --UBt 1200 --TBt 1000 --Ucd 700 --Tcd 2000 --preionization 1 --gas He --pressure 15 --comment "u_bias to 140 V" --diagnostics_langballpenprobe "r_LP_tip=50, f_fg=5000, u_fg=7, r_i=27" --ScanDefinition "0"
#36869     ./Dirigent.sh --discharge --UBt 1200 --TBt 1000 --Ucd 700 --Tcd 2000 --preionization 1 --gas He --pressure 15 --comment "Experimental set-up OK, going back with probe" --diagnostics_langballpenprobe "r_LP_tip=55, f_fg=5000, u_fg=7, r_i=27" --ScanDefinition "36868"
#36871     ./Dirigent.sh --discharge --UBt 1200 --TBt 1000 --Ucd 700 --Tcd 2000 --preionization 1 --gas He --pressure 15 --comment "60 again, bias offset changed" --diagnostics_langballpenprobe "r_LP_tip=60, f_fg=5000, u_fg=7, r_i=27" --ScanDefinition "36868 36869"
#36873     ./Dirigent.sh --discharge --UBt 1200 --TBt 1000 --Ucd 700 --Tcd 2000 --preionization 1 --gas He --pressure 15 --comment "65 again, u_bias to 160 V" --diagnostics_langballpenprobe "r_LP_tip=65, f_fg=5000, u_fg=8, r_i=27" --ScanDefinition "36868 36869 36871"
#36877     ./Dirigent.sh --discharge --UBt 1200 --TBt 1000 --Ucd 700 --Tcd 2000 --preionization 1 --gas He --pressure 15 --comment "PROBLEM with probe position, from 70 again" --diagnostics_langballpenprobe "r_LP_tip=70, f_fg=5000, u_fg=8, r_i=27" --ScanDefinition "36868 36869 36871 36873"

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Diagnostics

Other

Navigation