Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Tue Feb 11 12:44:59 2014
  • Number of spectra: 23
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.81
  • Board temperature [C]: 27.311
  • Time stamps [ms]: [ 1. 4.2715 7.5073 8.4411 10.7478 11.819 14.1187 15.0644 17.3686 18.4434 20.7434 21.8141 24.1285 25.1928 27.4911 28.439 30.7441 31.8178 34.1264 35.1896 37.4939 38.5681 40.8666]
  • Noise RMS [counts]: 9.9

Data [Source]

Measured spectra
All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation