Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Tue Feb 11 16:45:28 2014
  • Number of spectra: 23
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.68
  • Board temperature [C]: 28.311
  • Time stamps [ms]: [ 1. 2.0882 4.3885 5.4491 7.752 8.8292 11.1359 12.1992 14.5 15.4568 17.7601 18.8207 21.1251 22.2079 24.5099 25.4463 27.7502 28.8311 31.1356 32.198 34.5008 35.5794 37.8854]
  • Noise RMS [counts]: 9.8

Data [Source]

Measured spectra
All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation