Tokamak GOLEM - Shot Database - 20435

[Template source]
[WebLog]
Date: 2016-01-12 - 12:27:56
Session: SessionPreparation
Comment: BorekLeitl - BOLO_vacuum test zhasnuto

    Basic parameters: (compare)

  • Gas pressure pch:9.02->9.52 mPa (request: 0 mPa) WIKI
  • Working gas: None
  • Preionization: OFF
  • Chamber temperature: 40.00 C
  • CBt capacitors charged to: 600 V, triggered 5.0 ms WIKI
  • CBD capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • CCD capacitors charged to: 500 V, triggered 7.0 ms WIKI
  • CST capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • Max saturation of iron core transformator: 94% WIKI
  • Probability of breakdown: 0% WIKI
  • Time since session beginning: 3:07:17 h
WIKI
WIKI
WIKI
WIKI

Data Acquisition Systems (DAS):


TektronixDPO

NIstandard

Papouch_Za

Papouch_St

Papouch_Ko

Diagnostics:


PlasmaPosition_TO

Interferometer

Spectrometer

FastCamera

HXR

Analysis:


HistoricalAnalysis

ShotHomepage

AdvancedAnalysis

Spectrograms_TO

MultiCWT_TO

Impurities_TO

Students:

Guests:

Acknowledgement:


Thanks to the specific help and

Diagnostics

Analysis

DAS

Vacuum log

Other