Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Tue Oct 10 14:36:35 2017
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.67
  • Board temperature [C]: 25.936
  • Time stamps [ms]: [ 1. 3.2657 4.3337 6.6488 7.703 10.0071 11.0817 13.3805 14.3263 16.6502 17.7063 20.006 21.0772 23.3834 24.4555 26.7576 27.702 30.0088 31.0813 33.3825 34.4528 36.7754 37.7074 40.0059 41.0781 43.3829 44.4563 46.7585 47.7039]
  • Noise RMS [counts]: 353.7

Data [Source]

Measured spectra
All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation