Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Thu Jan 11 21:24:22 2018
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.78
  • Board temperature [C]: 25.998
  • Time stamps [ms]: [ 1. 3.3066 6.5611 9.8099 10.7572 13.0749 13.9962 16.2983 17.3749 19.6801 20.7448 23.0444 23.9963 26.2963 27.3699 29.6731 30.7459 33.0474 34.1196 36.4189 37.3703 39.6745 40.7443 43.0457 44.1214 46.422 47.3694 49.673 50.7464]
  • Noise RMS [counts]: 9.9

Data [Source]

Measured spectra
All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation