Tokamak GOLEM - Shot Database - 27058

[Template source]
[WebLog]
Date: 2018-04-23 - 17:16:56
Session: Experiments/HXR/TimepixDetector/VlLinh/0418Intro
Comment: maskomic - zmena el. proudu, 550+1001

    Basic parameters: (compare)

  • Gas pressure pch:2.07->15.39 mPa (request: 17 mPa) WIKI
  • Working gas: H
  • Preionization: Upper el. gun
  • Chamber temperature: 27.20 C
  • CBt capacitors charged to: 1001 V, triggered 5.0 ms WIKI
  • CBD capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • CCD capacitors charged to: 551 V, triggered 5.0 ms WIKI
  • CST capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • Probability of breakdown: 95% WIKI
  • Time since session beginning: 9:33:48 h