Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Thu Dec 13 18:29:48 2018
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.68
  • Board temperature [C]: 23.811
  • Time stamps [ms]: [ 1. 2.302 4.6021 5.678 7.9782 8.9227 11.2232 12.2987 14.6013 15.6733 17.9732 19.0503 21.3498 22.2971 24.5995 25.6749 27.975 29.0479 31.3488 32.4258 34.727 35.6735 37.9741 39.0507 41.3505 42.4238 44.7249 45.6755 47.9765]
  • Noise RMS [counts]: 10.9

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated