Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Thu Jan 17 11:25:50 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.67
  • Board temperature [C]: 23.936
  • Time stamps [ms]: [ 1. 2.0001 4.3048 5.256 7.5565 8.6263 10.927 12.0035 14.3034 15.373 17.6759 18.6286 20.9289 21.9986 24.3009 25.3771 27.6785 28.6259 30.9264 32.0024 34.3046 35.3739 37.6756 38.7544 41.054 41.9983 44.3006 45.3775 47.6779]
  • Noise RMS [counts]: 10.3

Data [Source]

No plasma

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated