Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Thu Jan 17 11:33:11 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.67
  • Board temperature [C]: 24.123
  • Time stamps [ms]: [ 1. 3.4005 4.3416 6.6366 7.711 10.0075 10.9572 13.2573 14.3284 16.6312 17.7119 20.0096 21.077 23.3817 24.3314 26.632 27.71 30.0068 31.0816 33.3839 34.3271 36.632 37.7115 40.0086 41.0774 43.386 44.331 46.6328 47.7098]
  • Noise RMS [counts]: 10.3

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated