Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Thu Jan 31 17:04:26 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.70
  • Board temperature [C]: 25.623
  • Time stamps [ms]: [ 1. 4.3293 5.2422 7.5433 8.4844 10.7884 11.8611 14.1607 15.2308 17.5343 18.4826 20.7806 21.8517 24.1563 25.2297 27.5272 28.5989 30.9018 31.8506 34.1498 35.2239 37.5244 38.5936 40.8951 41.9729 44.2717 45.2146 47.5185 48.5925]
  • Noise RMS [counts]: 10.5

Data [Source]

No plasma

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated