Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Thu Feb 7 17:52:43 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.71
  • Board temperature [C]: 22.436
  • Time stamps [ms]: [ 1. 3.3913 5.6274 6.58 8.8776 9.9459 12.245 13.3202 15.6193 16.57 18.8675 19.9419 22.2432 23.313 25.6131 26.5655 28.8643 29.9354 32.2351 33.3096 35.6104 36.6836 38.9833 39.9323 42.2325 43.3031 45.6024 46.6811 48.9791]
  • Noise RMS [counts]: 10.6

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated