Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Fri Feb 8 16:48:12 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.74
  • Board temperature [C]: 23.936
  • Time stamps [ms]: [ 1. 3.3153 6.5658 7.5049 9.8075 10.7482 13.0483 14.123 16.4228 17.494 19.7981 20.7443 23.0438 24.1154 26.4161 27.491 29.793 30.8629 33.1621 34.113 36.4131 37.4832 39.787 40.8592 43.157 44.2299 46.5311 47.4807 49.7828]
  • Noise RMS [counts]: 10.0

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated