Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Wed Mar 6 16:25:44 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.71
  • Board temperature [C]: 26.561
  • Time stamps [ms]: [ 1. 3.4067 5.6454 6.596 8.8964 9.9676 12.268 13.347 15.6447 16.5942 18.8934 19.9689 22.2688 23.344 25.6435 26.7196 29.0196 29.9672 32.269 33.3484 35.647 36.7183 39.0202 39.9689 42.2681 43.3473 45.6454 46.7206 49.0197]
  • Noise RMS [counts]: 10.3

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated