Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Mon Mar 18 16:29:42 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.68
  • Board temperature [C]: 25.498
  • Time stamps [ms]: [ 1. 2.2634 4.5536 5.6309 7.9574 9.0113 11.3157 12.3807 14.6822 15.6326 17.9281 19.004 21.3348 22.384 24.6782 25.629 27.932 29.0083 31.3122 32.3805 34.6831 35.7565 38.0519 39.0053 41.3171 42.3804 44.6781 45.7553 48.0581]
  • Noise RMS [counts]: 9.6

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated