Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Wed Mar 20 11:15:24 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.66
  • Board temperature [C]: 23.249
  • Time stamps [ms]: [ 1. 3.2758 4.2196 6.5182 7.4639 9.778 10.8413 13.14 14.2149 16.5158 17.4647 19.769 20.8402 23.1411 24.2166 26.5143 27.4649 29.7761 30.8423 33.1408 34.2157 36.5159 37.6095 39.8919 40.8413 43.1419 44.2178 46.5167 47.6128]
  • Noise RMS [counts]: 9.8

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated