Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Wed Mar 20 14:43:30 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.68
  • Board temperature [C]: 25.498
  • Time stamps [ms]: [ 1. 2.1175 4.4171 5.4812 7.7847 8.8582 11.1592 12.2313 14.5326 15.483 17.7849 18.8548 21.1576 22.237 24.5352 25.4803 27.7827 28.8587 31.1593 32.2325 34.5329 35.6099 37.9106 38.8552 41.1583 42.236 44.5354 45.606 47.908 ]
  • Noise RMS [counts]: 10.3

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated