Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Wed Mar 20 14:59:07 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.67
  • Board temperature [C]: 25.623
  • Time stamps [ms]: [ 1. 2.1244 4.4356 5.3674 7.6773 8.7446 11.0444 12.1161 14.4218 15.4942 17.8035 18.7403 21.0467 22.1197 24.4199 25.491 27.8062 28.8711 31.1698 32.1169 34.4248 35.4953 37.8042 38.8669 41.1729 42.1207 44.4211 45.4919 47.8058]
  • Noise RMS [counts]: 10.4

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated