Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Sat Mar 23 14:41:43 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.72
  • Board temperature [C]: 25.561
  • Time stamps [ms]: [ 1. 3.2934 5.5317 6.6049 8.9059 9.9794 12.2775 13.3521 15.6516 16.603 18.9051 19.9766 22.2767 23.3543 25.6524 26.7259 29.0285 29.9796 32.2793 33.3527 35.6519 36.7284 39.03 39.9777 42.2777 43.355 45.6544 46.7269 49.031 ]
  • Noise RMS [counts]: 10.9

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated