Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Mon Mar 25 11:52:51 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.78
  • Board temperature [C]: 25.748
  • Time stamps [ms]: [ 1. 3.2916 6.5474 9.7914 10.7251 13.0262 13.9707 16.2738 17.349 19.6506 20.5949 22.9071 23.9741 26.2749 27.3453 29.657 30.7234 33.0347 33.9706 36.2739 37.3501 39.6505 40.7207 43.034 44.0994 46.4018 47.3468 49.6494 50.725 ]
  • Noise RMS [counts]: 10.1

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated