Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Thu Apr 4 17:19:33 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.86
  • Board temperature [C]: 26.748
  • Time stamps [ms]: [ 1. 3.3324 6.5903 9.8331 13.082 14.039 16.3214 17.3973 19.6934 20.7678 23.0715 24.0385 26.3196 27.3941 29.6956 30.7711 33.0686 34.1458 36.4464 37.3978 39.6943 40.7699 43.071 44.1494 46.4455 47.3947 49.6972 50.7724 53.0695]
  • Noise RMS [counts]: 10.6

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated