Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Tue Apr 16 16:52:57 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.67
  • Board temperature [C]: 26.623
  • Time stamps [ms]: [ 1. 2.0689 4.3823 5.3437 7.622 8.6943 10.9946 12.0737 14.3686 15.4293 17.7547 18.6955 20.9944 22.069 24.3906 25.4458 27.7813 28.8202 31.1356 32.0704 34.3757 35.4315 37.7565 38.822 41.1211 42.0672 44.381 45.4402 47.7445]
  • Noise RMS [counts]: 10.1

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated