Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Thu May 23 19:57:04 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.74
  • Board temperature [C]: 27.186
  • Time stamps [ms]: [ 1. 3.3149 6.5667 7.5016 9.8006 10.7512 13.0504 14.1233 16.4245 17.5011 19.8011 20.7475 23.0496 24.125 26.4269 27.4977 29.7995 30.8759 33.1773 34.1236 36.425 37.5006 39.8054 40.8756 43.1759 44.2504 46.5546 47.4992 49.8002]
  • Noise RMS [counts]: 10.5

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated