Tokamak GOLEM - Shot Database - 30982
[Template source]
[WebLog]
Machine failure: Too low Uloop (MeanUloop < 3V);
Basic parameters: (compare)
- Gas pressure pch:0.82->9.96 mPa
(request: 10 mPa) WIKI
- Working gas:
H
- Preionization: Upper el. gun
- Chamber temperature: 37.30 C
- CBt capacitors charged to: 1300 V, triggered 5.0 ms WIKI
- CBD capacitors charged to: 0 V, triggered 5.0 ms WIKI
- CCD capacitors charged to: 450 V, triggered 5.0 ms WIKI
- CST capacitors charged to: 0 V, triggered 5.0 ms WIKI
- Max saturation of iron core transformator: 90% WIKI
- Level of noise (dBt) in room: 0.050 V
- Probability of breakdown: 95% WIKI
- Time since session beginning: 2:31:59 h
|
|
Data Acquisition Systems (DAS):
Diagnostics:
Analysis:
Students:
Guests:
Acknowledgement:
Thanks to the specific help