Tokamak GOLEM - Shot Database - 32368
The date of discharge execution | 20-04-25 20:45:08 |
---|
The session mission | Default setup |
---|
The session ID | 32353 |
---|
The discharge comment | Lepe .. |
Basic parameters:
- Working Gas: \(p\sub{chamber}\sup{discharge,before}\)=1,12 mPa; \(p\sub{chamber}\sup{discharge,pre}\)=15,10 mPa (\(p\sub{WG}\sup{request}\)= 15 mPa)
- Toroidal magnetic field: \(U\sub{B\sub{t}}\sup{request}\)=220 V@\(t\sub{B\sub{t}}\sup{request}\)=5,0 ms
- Current drive field: \(U\sub{E\sub{cd}}\sup{request}\)=200 V@\(t\sub{cd}\sup{request}\)=5,0 ms
|
Plasma parameters:
- Discharge duration: \(\tau\sub{p}\)=0,00 ms
- Loop voltage:\(\overline{U\sub{loop}}\)\(\)=5,36 V; \(\maximum{{\tau \in [discharge]}U\sub{loop}}\)=8,42 V
- Toroidal magnetic field: \(\overline{B\sub{t}}\)=0,07 T; \(\max_{\tau \in [discharge]}B\sub{t}\)=0,12 T
- Plasma current: \(\overline{I\sub{p}}\)=0,01 kA; \(\max_{\tau \in [discharge]}I\sub{p}\)=0,05 kA
|
Data Acquisition Systems (DAS):
Analysis:
Acknowledgement:
Thanks to the specific help
and