\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem #38481

Tokamak GOLEM - Shot Database - #38481

The date of discharge execution22-03-30 16:54:56 [Shot logbook]
The session mission22 --> Plasma position stabilization
The session ID38475
The discharge commentPlasma verti+rad
Discharge command./Dirigent.sh --discharge --UBt 900 --TBt 0 --Ucd 500 --Tcd 1000 --preionization 1 --gas H --pressure 10 --diagnostics.limitermirnovcoils "vacuum_shot=38478" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;8000,-20;20000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;9000,-20;15000,0;22000,-2;25000,0'" --discharge.preionization "main_switch='on',powsup_heater=80,powsup_accel=100" --ScanDefinition "38479 38480" --comment "Plasma verti+rad "

     Technological parameters

    Plasma:

    Plasma parameters:

Basic Diagnostics    

On stage diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 



         



 



         



 



Right now the tokamak GOLEM is undergoing discharge execution, the phase called:

OFF STAGE postdischarge analysis

Next phase will be Stand by.

Wait for the discharge proccess to be completed.

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Diagnostics

Other

Navigation