Tokamak GOLEM - Shot Database - 11796

[Template source]
[WebLog]
Date: 2013-04-11 - 17:55:37
Session:TrainingCourses/0413GOMTRAIC [new]
Comment: LukMat - Vacuum shot - HXR studies

Machine failure: Failure (UloopMax < 1V);Failure (BtMax) < 0.01T);

    Basic parameters: (compare)

  • Gas pressure pch:1.72->1.73 mPa (request: 0 mPa) WIKI
  • Working gas: None
  • Preionization: ON
  • Chamber temperature: N/A C
  • CBt capacitors changed to: 1200 V, triggered 5.0 ms WIKI
  • CBD capacitors changed to: 0 V, triggered 5.0 ms WIKI
  • CCD capacitors changed to: 500 V, triggered 6.0 ms WIKI
  • CST capacitors changed to: 0 V, triggered 5.0 ms WIKI
  • Probability of breakdown: 0% WIKI
  • Time since session beginning: 6:05:07 h
WIKI
WIKI
WIKI
WIKI

Data Acquisition Systems (DAS):


NIturbo

TektronixDPO

NIstandard

Papouch

Diagnostics:


PlasmaPosition

Interferometer

HXR

FastCamera

Spectrometer

Analysis:


AdvancedAnalysis

HistoricalAnalysis

ShotHomepage

MagFieldEvolution

Spectrograms

MultiCWT

Impurities

Acknowledgement:


Thanks to the specific help and

Diagnostics

Analysis

DAS

Vacuum log

Other