Shot #10497
»
Tokamak GOLEM - Shot Database - 10497
[Template source]
[WebLog]
Date:
2012-12-10 -
15:11:15
Session:
Technological/Vacuum/ChamberCleaning
[new]
Comment:
GOLEM_5let - Discharge comment
Machine failure: Failure (BtMax) < 0.01T);
Basic parameters:
(
compare
)
Gas pressure p
ch
:
5.89
->
27.88
mPa (request:
28
mPa)
WIKI
Working gas:
N/A
Preionization: ON
Chamber temperature:
N/A
C
C
B
t
capacitors changed to:
1400 V
, triggered
5.0 ms
WIKI
C
BD
capacitors changed to:
0 V
, triggered
5.0 ms
WIKI
C
CD
capacitors changed to:
500 V
, triggered
20.0 ms
WIKI
C
ST
capacitors changed to:
0 V
, triggered
5.0 ms
WIKI
Max saturation of iron core transformator:
89%
WIKI
Probability of breakdown:
90%
WIKI
Time since session beginning: 6:19:40 h
WIKI
WIKI
WIKI
WIKI
basicdiagn processing evolution:
raw
→
integrated
→
final
Basic diagnostics:
loop_voltage
,
plasma_current
,
toroidal_field
,
photodiode
,
hxr
,
other diagnostics
Data Acquisition Systems (DAS):
NIstandard
Diagnostics:
PlasmaPosition
FastCamera
Spectrometer
Analysis:
AdvancedAnalysis
HistoricalAnalysis
ShotHomepage
Impurities
Acknowledgement:
Thanks to the specific help
and
Diagnostics
✕
PlasmaPosition
✕
FastCamera
✕
Spectrometer
Analysis
✕
AdvancedAnalysis
✕
HistoricalAnalysis
✕
ShotHomepage
✕
Impurities
DAS
✕
NIstandard
Vacuum log
Charging log
Other
Data
References
About
Wiki
Utilities
Navigation
Next
Previous
Current
Go to shot
[Main template]
Disk usage: 29MB
Navigation
current
next
|
previous
|