Tokamak GOLEM - Shot Database - 12675

[Template source]
[WebLog]
Date: 2013-07-07 - 19:49:03
Session:Promotion/0713Bochum [new]
Comment: Bochum - Lower B

    Basic parameters: (compare)

  • Gas pressure pch:4.11->23.10 mPa (request: 24 mPa) WIKI
  • Working gas: N/A
  • Preionization: OFF
  • Chamber temperature: N/A C
  • CBt capacitors changed to: 300 V, triggered 5.0 ms WIKI
  • CBD capacitors changed to: 0 V, triggered 5.0 ms WIKI
  • CCD capacitors changed to: 500 V, triggered 6.0 ms WIKI
  • CST capacitors changed to: 0 V, triggered 5.0 ms WIKI
  • Max saturation of iron core transformator: 92% WIKI
  • Probability of breakdown: 14% WIKI
  • Time since session beginning: 0:59:47 h
WIKI
WIKI
WIKI
WIKI

Data Acquisition Systems (DAS):


NIturbo

TektronixDPO

NIstandard

Diagnostics:


PlasmaPosition

Interferometer

Spectrometer

FastCamera

HXR

Analysis:


HistoricalAnalysis

ShotHomepage

AdvancedAnalysis

Spectrograms

MultiCWT

Impurities

Acknowledgement:


Thanks to the specific help and

Diagnostics

Analysis

DAS

Vacuum log

Other

Navigation