Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Wed Feb 20 16:31:22 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.66
  • Board temperature [C]: 25.561
  • Time stamps [ms]: [ 1. 3.2974 4.242 6.5408 7.6039 9.9038 10.8541 13.155 14.223 16.5243 17.6028 19.9013 20.97 23.2708 24.2212 26.5213 27.5932 29.8934 30.9688 33.2684 34.3382 36.6394 37.5916 39.8914 40.9593 43.2615 44.3364 46.6375 47.5825]
  • Noise RMS [counts]: 10.3

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated