Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Wed Feb 20 16:34:10 2019
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.68
  • Board temperature [C]: 25.623
  • Time stamps [ms]: [ 1. 2.28 4.5647 5.6303 7.9346 9.0069 11.3069 12.2576 14.5533 15.628 17.929 18.9975 21.2991 22.3631 24.6752 25.619 27.9208 28.996 31.296 32.3509 34.668 35.6175 37.919 38.9872 41.2886 42.354 44.6661 45.734 48.037 ]
  • Noise RMS [counts]: 10.6

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated