echo "\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\)"; Golem No: 32964 - the only fully opensource tokamak

Tokamak GOLEM - Shot Database - 32964

The date of discharge execution20-05-26 11:02:27
The session missionTraining Course for MEPhI_Moscow
The session ID32963
The discharge commentDummy test discharge
Discharge command--discharge --UBt 0 --TBt 1000 --Ucd 0 --Tcd 2000 --preionization 1 --gas H --pressure 10 --Bt_orientation CW --CD_orientation CW --vacuum_shot -1 --comment Dummy test discharge

    Technological parameters:

  • Working Gas: \(p\sub{chamber}\sup{discharge,before}\)=0,62 mPa; \(p\sub{chamber}\sup{discharge,pre}\)=0,62 mPa (\(p\sub{WG}\sup{request}\)= 10 mPa)
  • Toroidal magnetic field: \(U\sub{B\sub{t}}\sup{request}\)= 0 V@\(t\sub{B\sub{t}}\sup{request}\)=1000,0 us
  • Current drive field: \(U\sub{E\sub{cd}}\sup{request}\)= 0 V@\(t\sub{cd}\sup{request}\)=1000,0 us

Data Acquisition Systems (DAS):


LimiterMirnovCoils

data

PetiSonda

data

StandardDAS

data

Analysis: