Golem No: 33265 - the only fully opensource tokamak

Tokamak GOLEM - Shot Database - 33265

The date of discharge execution20-06-12 17:12:53 [Shot logbook]
The session missionSandBox --> Control system development
The session ID33249
The discharge commentStandard test discharge
Discharge command./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 10 --Bt_orientation CW --CD_orientation CW --comment Standard test discharge

    Technological parameters:

    Plasma parameters:

  • Discharge duration: τp=6,50 ms
  • Loop voltage:Uloop¯=10,23 V; maxτ[discharge]Uloop=18,01 V
  • Toroidal magnetic field: Bt¯=0,19 T; maxτ[discharge]Bt=0,25 T
  • Plasma current: Ip¯=1,24 kA; maxτ[discharge]Ip=1,59 kA

Basic diagnostics

Data Acquisition Systems (DAS)

LimiterMirnovCoils

data dir
StandardDAS

data dir

Analysis

I. wave:BasicDiagnostics

data dir
II. wave:Homepage

data dir
InnerStabilization

data dir
III. wave:

Infrastructure

Chamber

data dir
Charger

data dir
Discharge

data dir
Operator

data dir

Acknowledgement


Thanks to the specific help

Diagnostics

Analysis

DASs

Vacuum log

Other