Golem No: 33387 - the only fully opensource tokamak

Tokamak GOLEM - Shot Database - 33387

[Web log]
The date of discharge execution20-07-07 12:15:17 [Shot logbook]
The session missionChargerWithHV_PowSup --> Wake up call after Brigada
The session ID33384
The discharge commentStandardni test dlouhodobe stability
Discharge command./Dirigent.sh --discharge --UBt 800 --Ucd 400 --Tcd 1000 --Tres 2000 --pressure 20 --preionization 1 --comment "Standardni test dlouhodobe stability"

    Technological parameters:

    Plasma parameters:

  • Discharge duration: τp=4,28 ms
  • Loop voltage:Uloop¯=10,42 V; maxτ[discharge]Uloop=13,48 V
  • Toroidal magnetic field: Bt¯=0,04 T; maxτ[discharge]Bt=0,05 T
  • Plasma current: Ip¯=-0,28 kA; maxτ[discharge]Ip=-0,19 kA

Basic diagnostics

Data Acquisition Systems (DAS)

StandardDAS

data dir

Analysis

0. wave:

BasicDiagnostics

data dir
Homepage

data dir
1. wave:

2. wave:

Infrastructure

Chamber

data dir
Charger

data dir
Discharge

data dir
Operator

data dir

Acknowledgement


Thanks to the specific help

Diagnostics

Analysis

  • --
  • --

DASs

Vacuum log

Other

Navigation